0
home

AccuTest Malaria Pf (HRP II) /Pv - Pack of 50 tests - Card Test - Accurex

home
AccuTest Malaria Pf (HRP II) /Pv - Pack of 50 tests - Card Test - Accurex
AccuTest Malaria Pf (HRP II) /Pv - Pack of 50 tests - Card Test - Accurex
Price And Quantity
  • Thousand
  • 1
  • Kit/Kits
  • 5250.00 INR
  • 5250.00 - 52500.00 INR
Product Specifications
  • Plastic
  • New
  • Other
  • Yes
  • Yes
  • No
  • No
  • NA
  • Blood Sample
  • Card
  • Accurex Accutest
  • Other
  • Wireless
  • Other Machines
  • Yes
  • Manual
  • Manual
  • Cassette
  • LED
  • 22.2 X 12.5 X 8.6
  • 400 Grams (g)
  • Whuite
  • Rust Proof, Latest Technology, Higher Level of Accuracy, Easy To Operate, Safe to Use, Sterilized, Flame Proof, Good Imagining Power
  • for the detection of malaria infection in human blood sample indicating differential diagnosis between Plasmodium falciparum and Plasmodium vivax species
    Product Description

    Precautions:

    • For in-vitro diagnostic use only.
    • The device is sensitive to humidity as well as to heat. So, its very important to take out the device from the sealed pouch just before use.
    • Do not use the kit after the expiration date.
    • Dispose all the samples and kits properly after test, in accordance with GLP.
    • Do not pipette reagent or blood by mouth.

    Specimen Collection & Storage: 

    • The test should be performed with freshly collected human blood from the fingertip or by vein puncture using sample tube containing anticoagulant.
    • For the short term storage, please keep the specimen at 2-8C, for the long term storage, please keep the sample below 20C.

    Procedure:

    • Allow AccuTest Malaria Pf (HRP II)/Pv kit component and specimens to attain room temperature.
    • Open the pouch and take out the device from it.
    • Label the device with patients identification.
    • Load 5ul of blood into the Sample port. (in case of fingertip blood, use single use lancet, wipe away first drop of blood and collect 5 ul with dropper provided and load to Sample port)
    • Add 4 drops of buffer solution into the Buffer port on the test device.
    • Wait for 15-20 minutes and read the result. The results should not be interpreted after 20 minutes.
    • Interpret the results. AccuTest Malaria Pf (HRP II) /Pv 

    Trade Information
    • EXW ABPL
    • 1000000 Per Day
    • 2 Days
    • Yes
    • Free samples available with shipping and taxes paid by the buyer
    • Test Device in aluminum pouch with desiccant & sample dropper Assay buffer
    • Asia, Australia, North America, South America, Eastern Europe, Western Europe, Middle East, Africa, Central America
    • All India
    • ISO
    Related Products



















    Send Inquiry



















    Send Inquiry


















    Send Inquiry


    Send Inquiry


    Send Inquiry
    right arrow
    left arrow
    Contact Us

    212, Udyog Mandir No. 17/C, Bhagoji Keer Marg, Mahim, Mumbai, Maharashtra, 400016, India
    Phone :+918045479256