0
home

Control & Calibrators Reagents

home
Showing 11 Items
ViewView
  1. Control for CBC 360 Neo

    brand name : ACCUREX BIOMEDICAL
    Send Inquiry
  2. AutoPure Homocysteine Control Low And High

    Introduction Homocysteine Control Low & High are intended to be used for quality control check during the determination of Homocysteine using Auto Pure Homocysteine kit. Control Storage, Stability & Handling Shelf - life & Stability Homocysteine Controls are stable until the expiration date printed on the vial label when stored at 2 - 8 degree C. Preparation of Control Homocysteine Controls are liquid, ready-to-use. DO NOT FREEZE.
    Send Inquiry
  3. AutoPure Homocysteine 5 Level Calibrator

    Introduction Homocysteine 5 level calibrator is intended to be used for the calibration of Homocysteine assay. Calibrator Storage, Stability & Handling Shelf - Life Unopened calibrators are stable when stored at 2 - 80C until the expiration date printed on the vial label. Preparation of Calibrator & Stability Homocysteine Calibrators are liquid, ready to use.DO NOT FREEZE. Calibrator Concentration Concentration of each calibrator is printed on the vial label. Indications of Deterioration Presence of extreme turbidity or microbial growth may indicate deterioration.
    Send Inquiry
  4. Autopure HbA1c Control Low And High 1

    Introduction HbA1c 4 level calibrator is intended to be used for the calibration of H bA1 c assay. Calibrator Storage, Stability & Handling Shelf- Life Unopened calibrators are stable when stored at 2 degree - 8 degree C until the expiration date printed on the vial label. Preparation of Calibrator & Stability Each lyophilized HbA1c calibrator should be reconstituted by adding 0.5 ml of distilled or deionized water. Close the vial and dissolve the contents by swirling gently to avoid formation of foam. Do not shake. Allow it to stand for 20 minutes before use. Reconstituted HbA1c calibrators are stable for 30 days at 2 degree - 8 degree C. DO NOT FREEZE.
    Send Inquiry
  5. Autopure - T-LDL Cholestrol-Calibrator

    Introduction T-LDL Calibrator is intended to be used for the calibration of HDL-C assay. Calibrator Storage, Stability & Handling Shelf - Life Unopened calibrator is stable when stored at 2 - 8 degree C until the expiration date printed on the vial label. Preparation of Calibrator & Stability Lyophilized serum T-LDL Calibrator should be reconstituted by adding 1.0 ml of distilled or deionized water. Close the vial and let stand for 20 minutes. Dissolve the contents of the vial by swirling gently to avoid the formation of foam. Do not shake. Reconstituted T-LDL Calibrator is stable for 14 days at 2 -8 degree C. Reconstitution stability of the calibrator may be extended upto 28 days by aliquoting and freezing the reconstituted calibrator preparation at less than -80 degree C.
    Send Inquiry
  6. Cystatine C control low And High

    brand name : ACCUREX BIOMEDICAL
    Send Inquiry
  7. ADA Control Low High

    INTRODUCTION Infinite ADA is a reagent set for direct quantitative determination of Adenosine deaminase (ADA) activity in human serum, plasma and other body fluids. Infinite ADA is a ready-to-use, two liquid reagent system. With Infinite ADA, the assay is linear upto 200 U/L. Infinite ADA assay can be performed in 11 minutes at 37 C. PRINCIPLE ADA catalyses deamination of adenosine to inosine which is then converted to hypoxanthine by purine nucleosidephosphorylase (PNP). Hypoxanthine is then converted to uric acid and hydrogen peroxide (H2O2) by xanthine oxidase (XOD). H2O2 is further reacted with N-Ethyl-N-(2-hydroxy-3-sulfopropyl)-3-methylaniline (EHSPT) and 4-aminoantipyrine (4 AAP) in the presence of peroxidase (POD) to generate quinone dye. denosine + H2O Inosine + NH3 PNP Inosine + Pi Hypoxanthine + Ribose-1-phosphate XOD Hypoxanthine + 2H2O + 2O2 Uric acid + 2 H2O2 POD 2 H2O2 + 4AAP + EHSPT 4 H2O + Quinone dye The intensity of the colour developed is directly proportional to the activity of ADA in the specimen and is measured kinetically.
    Send Inquiry
  8. ADA Calibrator

    INTRODUCTION Infinite ADA is a reagent set for direct quantitative determination of Adenosine deaminase (ADA) activity in human serum, plasma and other body fluids. Infinite ADA is a ready-to-use, two liquid reagent system. With Infinite ADA, the assay is linear upto 200 U/L. Infinite ADA assay can be performed in 11 minutes at 37 C. PRINCIPLE ADA catalyses deamination of adenosine to inosine which is then converted to hypoxanthine by purine nucleosidephosphorylase (PNP). Hypoxanthine is then converted to uric acid and hydrogen peroxide (H2O2) by xanthine oxidase (XOD). H2O2 is further reacted with N-Ethyl-N-(2-hydroxy-3-sulfopropyl)-3-methylaniline (EHSPT) and 4-aminoantipyrine (4 AAP) in the presence of peroxidase (POD) to generate quinone dye. denosine + H2O Inosine + NH3 PNP Inosine + Pi Hypoxanthine + Ribose-1-phosphate XOD Hypoxanthine + 2H2O + 2O2 Uric acid + 2 H2O2 POD 2 H2O2 + 4AAP + EHSPT 4 H2O + Quinone dye The intensity of the colour developed is directly proportional to the activity of ADA in the specimen and is measured kinetically.
    Send Inquiry
  9. HbA1c 4 Level Calibrator

    Introduction HbA1c 4 level calibrator is intended to be used for the calibration of H bA1 c assay. Calibrator Storage, Stability & Handling Shelf- Life Unopened calibrators are stable when stored at 2 degree - 8 degree C until the expiration date printed on the vial label. Preparation of Calibrator & Stability Each lyophilized HbA1c calibrator should be reconstituted by adding 0.5 ml of distilled or deionized water. Close the vial and dissolve the contents by swirling gently to avoid formation of foam. Do not shake. Allow it to stand for 20 minutes before use. Reconstituted HbA1c calibrators are stable for 30 days at 2 degree - 8 degree C. DO NOT FREEZE.
    Send Inquiry
  10. Autopure T HDL Cholestrol Calibrator

    Introduction T HDL-C Calibrator is intended to be used for the calibration of HDL-C assay. Calibrator Storage, Stability & Handling Shelf - Life Unopened calibrator is stable when stored at 2 - 8 degree C until the expiration date printed on the vial label. Preparation of Calibrator & Stability Lyophilized serum T HDL-C Calibrator should be reconstituted by adding 1.0 ml of distilled or deionized water. Close the vial and let stand for 20 minutes. Dissolve the contents of the vial by swirling gently to avoid the formation of foam. Do not shake. Reconstituted T HDL-C Calibrator is stable for 14 days at 2 -8 degree C. Reconstitution stability of the calibrator may be extended upto 28 days by aliquoting and freezing the reconstituted calibrator preparation at less than -80 degree C.
    Send Inquiry
Contact Us

212, Udyog Mandir No. 17/C, Bhagoji Keer Marg, Mahim, Mumbai, Maharashtra, 400016, India
Phone :+918045479256