Phosphorus 80

home
Phosphorus 80
Phosphorus 80
Price And Quantity
  • Kit/Kits
  • 1
  • Kit/Kits
  • 1729 INR
    Product Specifications
    • Liquid
    • Other
    • other
    • Other
    • Biochemistry Reagent
    • AutoPure Phosphorus is ready to use, single liquid reagent system. With AutoPure Phosphorus, the assay is linear upto 20 mg/dl (6.46 mmo1/1).
    • 18 Months
    • Biochemistry Reagent
    • Reagents
    • Other
    • ACC90598
    • Industrial
    • Industrial Lab Chemicals
    • 95%
      Product Description
      Introduction
      • AutoPure Phosphorus is a reagent kit for direct quantitative determination of phosphorus in human serum and plasma on automated clinical chemistry analyzers.
      • AutoPure Phosphorus is ready to use, single liquid reagent system.
      • With AutoPure Phosphorus, the assay is linear upto 20 mg/dl (6.46 mmo1/1).
      Principle

      Inorganic phosphorus reacts with ammonium molybdate at acidic pH to form ammonium - phosphomolybdate complex.

      Phosphorus + Ammonium molybdate-  Ammonium- phospho-molybdate complex

      The absorbance of this complex formed is directly proportional to the concentration of phosphorus in the specimen and is measured photometrically.

      Reagent Storage, Stability & Handling

      AutoPure Phosphorus is ready-to-use, single liquid reagent system.

      Shelf life

      Stable till the expiry date indicated on the label, when stored at 15 -25C.

      On   Board Reagent Stability

      45 days at 2 - 8 C after opening .

      Protect the reagent from light and contamination.

      Do not freeze the reagent.

      Components & Concentration of Working Solution 

      Components                                                                     Concentration

       

      • Ammonium molybdate                                          0.4 mmol/l
      • Sulphuric acid                                                            0.25 mmol
      • Stabilizers, excipients & surface active agents

       

      Specimen Collection & Preservation

      Collect sample using standard sampling tube. Serum, heparinized plasma or EDTA plasma can be used. Avoid haemolyzed samples as haemolysis interferes with the assay. Phosphorus in serum/plasma is stable for 8 hours at 20-25C, 24 hours at 2- 8C and 1year at -20C (when frozen only once). Centrifuge samples containing precipitate before performing assay.

      Calculations

      Fully automated system automatically calculates the Phosphorus concentration of each sample.

      Results in mmo1/1= Results in mg/di x 0.323

      Application Sheet

      Refer to application sheet for details. For additional system applications, contact our local Accurex representative.

      Calibration

      For calibration it is recommended to use C.f.a.s or any other suitable calibrator material.

      Calibration frequency

      Re calibration is recommended

       

      • Whenever the reagent lot is changed.
      • As per the requirement of quality control procedures.  

       

      Quality Control
      Each batch ofAutoPure Phosphorus is assayed with atleast six quality control sera - Precinorm Precipath, Biorad 1, Biorad 11, Accutrol Normal and Accutrol Abnormal prior to release
      To ensure adequate quality control, it is recommended that the laboratory should use a normal and abnormal commercial reference control serum. It should be realized that the use of quality control material checks both the reagent and instrument functions together.

      If the control values fall outside the specified limits, each of the below criteria should be cross - checked and corrected:

       

      • Proper instrument function   wavelength setting, light source and temperature control.
      • Cleanliness of probes and cuvettes.
      • Bacterial contamination of wash water used by the instrument.
      • Expiry date of the reagent kit.

       

      Expected Values

      Serum/ Plasma

      Adults

      2.7-4.5 mg/dl ( 0.87-1.45 mmol/l)

      Children

      4.0 6.5 mg/dl ( 1.29 .2.1mmol/l)

       Note:

      Expected range varies from population to population. It is therefore recommended that each laboratory should establish its own normal range. For diagnostic purposes, the phosphorus results should always be assessed in conjunction with the patient's medical history, clinical examinations and other findings.

       Performance Characteristics Linearity

      With AutoPure Phosphorus, the assay is linear upto 20 mg/di (6.46 mmo1/1). Determine samples with higher concentrations via the rerun function. On instruments without rerun function, manually dilute samples with higher concentrations using 0.9% NaCI or distilled/deionized water (e.g. 1 + 4). Multiply the result by the appropriate dilution factor (e.g. 5).

      Interference

      There is no significant interference in samples containing upto 40 mg/di of bilirubin. Haemolysis interferes at approximate haemoglobin concentration of 300 mg/d1. Note: On haemolysis, red blood cells release phosphatases and organic phosphates. Both of these react to produce inorganic phosphates which interfere in the reaction.

      Precision

      Reproducibility was determined using quality control sera as shown below


      Within run

      Between run

      Quality Control Material

      Means gdl

      SD gdl

      CV

      Means gdl

      SD gdl

      CV

      Low Control Serum

      3.91

      0.08

      2.00

      4.05

      0.12

      3.0

      High Control Serum

      6.29

      0.08

      1.3

      5.97

      0.13

      2.2

       Co - Relation Studies

      A comparison of the Phosphorus determination using AutoPure Phosphorus and AutoZyme Phosphorus reagent gave the following co-relation (mg/dl):

      Linear Regression

      y= 1.012x+ 0.016

      r= 0.998

      Sy.x = 0.08

      No of samples measured : 65

      The sample concentrations measured were between 3 mg/di and 8 mg/dl..

      References 

      • Tietz, N.W., ed. Clinical Guide to Laboratory Tests, 3rd ed. Philadelphia, Pa : W.B. Saunders, 1995: 486 - 487.
      • Burtis CA, Ashwood E.R., editors. Tietz Textbook of Clinical Chemistry, 2nd ed. Philadelphia, WB Saunders 1994:1909.
      • Garnst O. and Try, K., Scand. J. Chi, Lab. Invest. 40, 1980.
      Trade Information
      • EXW ABPL
      • Paypal, Letter of Credit at Sight (Sight L/C), Letter of Credit (L/C), Cheque, Cash in Advance (CID), Cash Against Delivery (CAD)
      • 10000 Per Day
      • 2 Days
      • Yes
      • packaging : Empity
      • Africa, Middle East, Western Europe, Eastern Europe, South America, North America, Central America, Australia, Asia
      • All India
      • certification : iso
      Related Products
      Glucose  STAT 600
















      Send Inquiry
      LDH 48
















      Send Inquiry
      Autopure - T-LDL Cholestrol-Calibrator
















      Send Inquiry
      BUN 500 - Infinite
















      Send Inquiry
      ADA 33
















      Send Inquiry
      Sphera System Solution (6 x 50ml)















      Send Inquiry
      right arrow
      left arrow
      Contact Us

      212, Udyog Mandir No. 17/C, Bhagoji Keer Marg, Mahim, Mumbai, Maharashtra, 400016, India
      Phone :+918045479256